800G OSFP DR8 SM MPO12 Optical Transceiver IB

Features

  • Form Factor: Hot-pluggable OSFP800 form factor
  • Data Rate: Aggregate data rate of 850 Gb/s and Breakout data rate of 106.25 Gb/s
  • Optical Interface: Compliant to 2×400GBASE-DR4 and 8x100GBASE-DR
  • Electrical Interface: Compliant to 2×400GAUI-4 and 8x100GAUI-1
  • Management Interface: I2C management interface
  • Reach: Up to 500m over MPO/APC single mode fiber
  • Power consumption: 16 W max
  • Operating case temperature: 0 ~ 70 ℃
  • Power Supply: Single 3.3V power supply

Compliance
  • Form Factor: OSFP MSA Rev 5.0
  • Optical: IEEE802.3cd /IEEE802.3bs
  • Electrical: IEEE802.3ck
  • Firmware: CMIS 5.2
  • Environment: RoHS
  • Stability: GR-468-CORE

Applications
  • 800Gb/s Ethernet
  • Data Center
  • 产品详细信息


OSFP 800G DR8 SM MPO12 IB Transceiver

NVIDIA twin port transceiver
800G ,2xNDR, OSFP, 2xMPO12 APC, 1310nm SMF, up to 100m, finned.


Functional Block Diagram

800G OSFP DR8


General Description

The 800G OSFP DR8 are high-performance, cost-effective transceivers designed for utilization in 800 Gigabit Ethernet links over 500 meters. On transmitter side, the module converts eight channels of 53.125 GBaud (PAM4) electrical data to eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4). At receiver side, the module converts eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4) into eight channels of 53.125 GBaud(PAM4) electrical output data.


The product is designed according to the OSFP MSA. It is designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.


Absolute Maximum Ratings and Recommended Operating Conditions

Absolute Maximum Ratings

Parameter

Symbol

Min

Typical

Max

Unit

Storage Temperature

Ts

-40


85

°C

Relative Humidity (non-condensation)

RH

15


85

%

Supply Voltage

Vcc

-0.5


3.6

V

Optical Input Power, per Lane

PIN



5.0

dBm


Recommended Operating Conditions

Parameter

Symbol

Min


Max

Unit

Operating Case Temperature

TC

0


70

°C

Signaling Rate, each lane



53.125


GBd

Data Rate Accuracy


-100


100

ppm

Power Supply Voltage

VCC

3.135

3.3

3.465

V

Pre-FEC Bit Error Ratio




2.4E-4


Transmission Distance




500

m


Optical Specifications

Optical Transmitter

Transmitter optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4


Lane wavelength

λ

1304.5

1311.0

1317.5

nm

Side-mode suppression ratio

SMSR

30



dB

Average launch power, each lanea

AOPTX

-2.9


4.0

dBm

Outer Optical Modulation

Amplitude (OMAouter), each laneb

OMATX

-0.8



dBm

Launch power in OMAouter minus TDECQ, each lane


-2.2



dBm

Transmitter and dispersion eye closure

 for PAM4, each lane

TDECQ



3.4

dB

Average launch power of OFF transmitter, each lane

AOPOFF



-15

dBm

Extinction ratio, each lane

ER

3.5



dB

RIN21.4OMA




–136

dB/Hz

Optical return loss tolerance

RLTol



21.4

dB

Transmitter reflectancec

Reflectance_

Tx



-26

dB

Note:

a. Average launch power, each lane (min) is informative and not the principal indicator of signal strength. A transmitter with launch power below this value cannot be compliant; however, a value above this does not ensure compliance.

b. Even if the TDECQ < 1.4 dB, the OMAouter (min) must exceed these values.

c. Transmitter reflectance is defined looking into the transmitter.

3.2 Optical Receiver


Receiver optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4

-

Lane wavelengths

λ

1304.5

1311.0

1317.5

nm

Damage threshold, each lanea

DThd

5



dBm

Average receive power, each laneb

AOPRX

-5.9


4

dBm

Receiver reflectance

Reflectance_

Rx



-26

dB

Receiver sensitivity (OMAouter), each lanec

RxSens



-4.4

dBm

Stressed receiver sensitivity (OMAouter), each laned

SRS



-1.9

dBm

Conditions of stressed receiver sensitivity test:e

Stressed eye closure for PAM4 (SECQ), lane under test



3.4


dB

OMAouter of each aggressor lane



4.2


dBm

Rx LOS

LOS Assert

LOSA

-15


-7.9

dBm

LOS De-assert

LOSD



-7.4

dBm

LOS Hysteresis

LOSH

0.5


5

dB

Notes:

a. The receiver shall be able to tolerate, without damage, continuous exposure to an optical input signal having this average power level. The receiver does not have to operate correctly at this input power.

b. Average receive power, each lane (min) is informative and not the principal indicator of signal strength. A received power below this value cannot be compliant; however, a value above this does not ensure compliance.

c. Receiver sensitivity (OMAouter), each lane (max) is informative and is defined for a transmitter with SECQ of 0.9 dB.

d. Measured with conformance test signal at TP3 for the BER = 2.4E-4.

e. These test conditions are for measuring stressed receiver sensitivity. They are not characteristics of the receiver.


Digital Diagnostic Monitor Accuracy

The following characteristics are defined over recommended operating conditions.

Parameter

Accuracy

Unit

Internally Measured Transceiver Temperature

+/-3

Internally Measured Transceiver Supply Voltage

+/-3

%

Measured Tx Bias Current

+/-10

%

Measured Tx Output Power

+/-3

dB

Measured Rx Received Average Optical Power

+/-3

dB


Pin Assignment and Description

The OSFP module pinout and connector pin list are as follows:

800G OSFP DR8


Mechanical Dimensions

Package dimensions in mm are specified in OSFP MSA.

800G OSFP DR8

Package dimensions


Ordering Information

Part Number

Temperature

Range

Distance

Media Connector

Fiber Type

E/O

O/E

R12OSFP-800G-DR8

0 to 70℃

500m

Dual MPO-12

SMF

Siph PIC

Siph PD

R16OSFP-800G-DR8

0 to 70℃

500m

MPO-16

SMF

Siph PIC

Siph PD




想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
800G QSFP-DD 800G QSFP-DD SR8 850nm 100m MPO-16 APC
Features QSFP-DD Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface MPO-16 APC connector 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 QSFP-DD MSA Compliant Hot Pluggable QSFP-DD form factor Compliant to QSFP-DD-Hardware-Rev 6.3 MSA Compliant to CMIS 5.2 Support Protocol Compliant to IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃
DCI 4x100G QSFP28 转400G CFP2 DCO 板卡 FW841
产品特性: 单板支持4*100G转400G相干传输,可实现单路400G线路侧传输。 波长可调,支持最大400G 75GHz * 64波,400G 100GHz*48波。 具备灵活的相干调制技术:DP-16QAM,DP-8QAM,DP-QPSK。 具备多种FEC纠错技术:oFEC,CFEC,SCFEC,SDFEC。 支持灵活业务接入功能:100GE, 100GE KR4, OTU4和100G FlexE。 支持完善的性能监控和统计功能。 支持高精度板卡温度,电压,电流及功耗实时监控。 客户侧支持多种模块接口类型:100GSR4/CWDM4/LR4/PSM4。 支持统一网管平台,网管方式SNMP、CLI、Web、NMS(图形化界面)。
ODF光纤线配架 ODF光纤线配架
全模块化设计,全正面化操作,集熔纤配线一体 大径盘绕设计使尾纤和跳纤的弯曲曲率半径保持在40mm以上 采用抽屉式一体化托盘,操作时可抽出,完毕后放回 适用带状和非带状光缆和FC、SC、ST和LC等多种适配器 适配器30°安装,既保证跳线弯曲曲率半径,又避免激光灼伤人眼, 操作方便,保护完善
光纤反射器 1650nm光纤反射器LC/APC
1650nm光纤反射器应用于FTTX光缆网络对光缆的监控 低损耗、使用寿命长、稳定可靠、温度特性小
Dual Fiber 8CH CWDM MUX DEMUX 8路 双纤双向 1470-1610nm CWDM 波分复用 LGX 盒子模块
CWDM MUX DEMUX,Multiplexing up to 8 Channels on Fiber Pair Passive, Protocol Transparent for Ethernet, FC, OTN, SONET/SDH, etc. Fully Compatible with All ITU-T 1G/10G/25G CWDM Optics Applied to Metro, Regional CWDM Networks
800G QSFP-DD 800G QSFP-DD SR8 850nm 100m MPO-16 APC
Features QSFP-DD Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface MPO-16 APC connector 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 QSFP-DD MSA Compliant Hot Pluggable QSFP-DD form factor Compliant to QSFP-DD-Hardware-Rev 6.3 MSA Compliant to CMIS 5.2 Support Protocol Compliant to IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃
100G QSFP28 DWDM 40GBASE-SR Bi-Directional QSFP+ 850/900nm 100m DOM LC MMF Optical Transceiver Module
40G QSFP+ BIDI optical transceiver module is a pluggable optical transceiver with a duplex LC connector interface for short-reach data communication and interconnect applications using Multi-Mode Fiber (MMF). It offers customers a compelling solution that enables reuse of their existing 10 Gb duplex MMF infrastructure for migration to 40 Gigabit Ethernet connectivity.