800G OSFP DR8 SM MPO12 Optical Transceiver IB

Features

  • Form Factor: Hot-pluggable OSFP800 form factor
  • Data Rate: Aggregate data rate of 850 Gb/s and Breakout data rate of 106.25 Gb/s
  • Optical Interface: Compliant to 2×400GBASE-DR4 and 8x100GBASE-DR
  • Electrical Interface: Compliant to 2×400GAUI-4 and 8x100GAUI-1
  • Management Interface: I2C management interface
  • Reach: Up to 500m over MPO/APC single mode fiber
  • Power consumption: 16 W max
  • Operating case temperature: 0 ~ 70 ℃
  • Power Supply: Single 3.3V power supply

Compliance
  • Form Factor: OSFP MSA Rev 5.0
  • Optical: IEEE802.3cd /IEEE802.3bs
  • Electrical: IEEE802.3ck
  • Firmware: CMIS 5.2
  • Environment: RoHS
  • Stability: GR-468-CORE

Applications
  • 800Gb/s Ethernet
  • Data Center
  • 产品详细信息


OSFP 800G DR8 SM MPO12 IB Transceiver

NVIDIA twin port transceiver
800G ,2xNDR, OSFP, 2xMPO12 APC, 1310nm SMF, up to 100m, finned.


Functional Block Diagram

800G OSFP DR8


General Description

The 800G OSFP DR8 are high-performance, cost-effective transceivers designed for utilization in 800 Gigabit Ethernet links over 500 meters. On transmitter side, the module converts eight channels of 53.125 GBaud (PAM4) electrical data to eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4). At receiver side, the module converts eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4) into eight channels of 53.125 GBaud(PAM4) electrical output data.


The product is designed according to the OSFP MSA. It is designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.


Absolute Maximum Ratings and Recommended Operating Conditions

Absolute Maximum Ratings

Parameter

Symbol

Min

Typical

Max

Unit

Storage Temperature

Ts

-40


85

°C

Relative Humidity (non-condensation)

RH

15


85

%

Supply Voltage

Vcc

-0.5


3.6

V

Optical Input Power, per Lane

PIN



5.0

dBm


Recommended Operating Conditions

Parameter

Symbol

Min


Max

Unit

Operating Case Temperature

TC

0


70

°C

Signaling Rate, each lane



53.125


GBd

Data Rate Accuracy


-100


100

ppm

Power Supply Voltage

VCC

3.135

3.3

3.465

V

Pre-FEC Bit Error Ratio




2.4E-4


Transmission Distance




500

m


Optical Specifications

Optical Transmitter

Transmitter optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4


Lane wavelength

λ

1304.5

1311.0

1317.5

nm

Side-mode suppression ratio

SMSR

30



dB

Average launch power, each lanea

AOPTX

-2.9


4.0

dBm

Outer Optical Modulation

Amplitude (OMAouter), each laneb

OMATX

-0.8



dBm

Launch power in OMAouter minus TDECQ, each lane


-2.2



dBm

Transmitter and dispersion eye closure

 for PAM4, each lane

TDECQ



3.4

dB

Average launch power of OFF transmitter, each lane

AOPOFF



-15

dBm

Extinction ratio, each lane

ER

3.5



dB

RIN21.4OMA




–136

dB/Hz

Optical return loss tolerance

RLTol



21.4

dB

Transmitter reflectancec

Reflectance_

Tx



-26

dB

Note:

a. Average launch power, each lane (min) is informative and not the principal indicator of signal strength. A transmitter with launch power below this value cannot be compliant; however, a value above this does not ensure compliance.

b. Even if the TDECQ < 1.4 dB, the OMAouter (min) must exceed these values.

c. Transmitter reflectance is defined looking into the transmitter.

3.2 Optical Receiver


Receiver optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4

-

Lane wavelengths

λ

1304.5

1311.0

1317.5

nm

Damage threshold, each lanea

DThd

5



dBm

Average receive power, each laneb

AOPRX

-5.9


4

dBm

Receiver reflectance

Reflectance_

Rx



-26

dB

Receiver sensitivity (OMAouter), each lanec

RxSens



-4.4

dBm

Stressed receiver sensitivity (OMAouter), each laned

SRS



-1.9

dBm

Conditions of stressed receiver sensitivity test:e

Stressed eye closure for PAM4 (SECQ), lane under test



3.4


dB

OMAouter of each aggressor lane



4.2


dBm

Rx LOS

LOS Assert

LOSA

-15


-7.9

dBm

LOS De-assert

LOSD



-7.4

dBm

LOS Hysteresis

LOSH

0.5


5

dB

Notes:

a. The receiver shall be able to tolerate, without damage, continuous exposure to an optical input signal having this average power level. The receiver does not have to operate correctly at this input power.

b. Average receive power, each lane (min) is informative and not the principal indicator of signal strength. A received power below this value cannot be compliant; however, a value above this does not ensure compliance.

c. Receiver sensitivity (OMAouter), each lane (max) is informative and is defined for a transmitter with SECQ of 0.9 dB.

d. Measured with conformance test signal at TP3 for the BER = 2.4E-4.

e. These test conditions are for measuring stressed receiver sensitivity. They are not characteristics of the receiver.


Digital Diagnostic Monitor Accuracy

The following characteristics are defined over recommended operating conditions.

Parameter

Accuracy

Unit

Internally Measured Transceiver Temperature

+/-3

Internally Measured Transceiver Supply Voltage

+/-3

%

Measured Tx Bias Current

+/-10

%

Measured Tx Output Power

+/-3

dB

Measured Rx Received Average Optical Power

+/-3

dB


Pin Assignment and Description

The OSFP module pinout and connector pin list are as follows:

800G OSFP DR8


Mechanical Dimensions

Package dimensions in mm are specified in OSFP MSA.

800G OSFP DR8

Package dimensions


Ordering Information

Part Number

Temperature

Range

Distance

Media Connector

Fiber Type

E/O

O/E

R12OSFP-800G-DR8

0 to 70℃

500m

Dual MPO-12

SMF

Siph PIC

Siph PD

R16OSFP-800G-DR8

0 to 70℃

500m

MPO-16

SMF

Siph PIC

Siph PD




想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
800G QSFP-DD 800G QSFP-DD SR8 850nm 100m MPO-16 APC
Features QSFP-DD Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface MPO-16 APC connector 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 QSFP-DD MSA Compliant Hot Pluggable QSFP-DD form factor Compliant to QSFP-DD-Hardware-Rev 6.3 MSA Compliant to CMIS 5.2 Support Protocol Compliant to IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃
3G Video  SFP  Transceiver 3G Video CWDM SFP Optical Transceiver support 1080P 60HZ Video
3G Video CWDM SFP optical transceiver module, support 1080p 60HZ video  and up to 80 km transmission. It works in optical video transmission.
SFP+ 16G DWDM 20KM Transceiver SFP+ 16G C17-C61 DWDM 20KM DDM Optical Transceiver
Product Features Supports up to 14.025Gbps bit rates Hot-pluggable SFP+ footprint 100GHz ITU, C Band DWDM Cooled EML laser and PIN photodiode, Up to 20km for SMF transmission Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle Compatible with RoHS Single +3.3V power supply Real Time Digital Diagnostic Monitoring Operating case temperature: Standard:  0 to +70°C Applications 4.25/8.5/14.025G Fibre channel Other Optical links
32×32光纤交换机1270-1610nm单模 LC/UPC 1U机架 32×32光纤交换机1270-1610nm单模LC/UPC 1U机架
FiberWDM(瑞东科技)的 MEMS 光开关 FW-OSS-32X32是一款高性能、全无阻塞且端口可配置的全光矩阵交换机,采用一系列专利技术。FW-OSS-32X32 包含 64 个对等光纤端口,可自由实现一对一连接。由于没有硬件定义的输入或输出端口,通过 FiberWDM 开发的图形用户界面(GUI)和嵌入式软件,FW-OSS-32X32 可配置为任意对称(N×N)或非对称(N×M)交换机组合。此外,通过软件定义分组,所有端口可划分为任意数量的组,每组端口数仅受总端口数限制,且每组可独立控制。软件控制与对等光纤端口连接的结合,为客户优化解决方案带来了更高水平的灵活性和可能性。FW-OSS-32X32 是一款多功能、易部署的高性能光开关,适用于多种应用场景。
光开关切换设备 光纤第二路由自动切换保护设备RD-OLP 支持8路主备光纤切换
支持应用于各种光通信系统; 支持双纤、单纤传输网络线路保护; 支持自动或手动切换多种工作模式; 支持主备路由实时监测; 支持掉电、上电保持功能; OLP功能板与网元管理板相互独立,互不影响; 支持SNMP、Web等多种图形化界面网管; 2U插卡式设计,容量灵活配置支持 交流220V、直流-48V供电可选,1+1电源输入保护;
以太网单向网闸 以太网单向网闸 千兆以太网单向传输设备 FW801
产品特点 物理隔离保障:光纤单向传输设备通过单向光纤通道,确保信息在传输过程中只能单向流动。这种物理隔离机制有效地防止了任何可能的信息泄露和未授权访问。 高度可靠性:我们的产品采用高品质的光纤技术和可靠的传输协议,确保信息传输的完整性和稳定性。设备内部的纠错和校验机制进一步增强了传输的可靠性,有效地减少了数据丢失或损坏的风险。 安装简单:无需复杂的安装流程,即插即用,简易上手。
48 口 25G/10G+8口100G 网络分流器 网络流量复制器 汇聚分流 TAP交换机 RD-TAP-48Y8C 48 口 25G/10G+8口100G 网络分流器 网络流量复制器 汇聚分流 TAP交换机 RD-TAP-48Y8C
19英寸标准机架式,1RU高度 48口SFP28 + 8口QSFP28; 支持48个25GE/10GE/GE(SFP28)和8个100GE/40GE(QSFP28) 1个RJ45管理网口,1个RJ45串口 双路冗余电源 支持标准五元组、输入接口、VLAN ID、固定位置特征码过滤 支持VLAN、MPLS标签识别剥离 支持不低于2层VLAN、6层MPLS、IPinIP、GTP-U、GRE、VXLAN、ERSPAN隧道报文的识别 支持CLI、SNMP、WEB管理、WEB管理支持HTTPS
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系