800G OSFP DR8 SM MPO12 Optical Transceiver IB

Features

  • Form Factor: Hot-pluggable OSFP800 form factor
  • Data Rate: Aggregate data rate of 850 Gb/s and Breakout data rate of 106.25 Gb/s
  • Optical Interface: Compliant to 2×400GBASE-DR4 and 8x100GBASE-DR
  • Electrical Interface: Compliant to 2×400GAUI-4 and 8x100GAUI-1
  • Management Interface: I2C management interface
  • Reach: Up to 500m over MPO/APC single mode fiber
  • Power consumption: 16 W max
  • Operating case temperature: 0 ~ 70 ℃
  • Power Supply: Single 3.3V power supply

Compliance
  • Form Factor: OSFP MSA Rev 5.0
  • Optical: IEEE802.3cd /IEEE802.3bs
  • Electrical: IEEE802.3ck
  • Firmware: CMIS 5.2
  • Environment: RoHS
  • Stability: GR-468-CORE

Applications
  • 800Gb/s Ethernet
  • Data Center
  • 产品详细信息


OSFP 800G DR8 SM MPO12 IB Transceiver

NVIDIA twin port transceiver
800G ,2xNDR, OSFP, 2xMPO12 APC, 1310nm SMF, up to 100m, finned.


Functional Block Diagram

800G OSFP DR8


General Description

The 800G OSFP DR8 are high-performance, cost-effective transceivers designed for utilization in 800 Gigabit Ethernet links over 500 meters. On transmitter side, the module converts eight channels of 53.125 GBaud (PAM4) electrical data to eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4). At receiver side, the module converts eight channels of parallel optical signals with data rate of 53.125 GBaud (PAM4) into eight channels of 53.125 GBaud(PAM4) electrical output data.


The product is designed according to the OSFP MSA. It is designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.


Absolute Maximum Ratings and Recommended Operating Conditions

Absolute Maximum Ratings

Parameter

Symbol

Min

Typical

Max

Unit

Storage Temperature

Ts

-40


85

°C

Relative Humidity (non-condensation)

RH

15


85

%

Supply Voltage

Vcc

-0.5


3.6

V

Optical Input Power, per Lane

PIN



5.0

dBm


Recommended Operating Conditions

Parameter

Symbol

Min


Max

Unit

Operating Case Temperature

TC

0


70

°C

Signaling Rate, each lane



53.125


GBd

Data Rate Accuracy


-100


100

ppm

Power Supply Voltage

VCC

3.135

3.3

3.465

V

Pre-FEC Bit Error Ratio




2.4E-4


Transmission Distance




500

m


Optical Specifications

Optical Transmitter

Transmitter optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4


Lane wavelength

λ

1304.5

1311.0

1317.5

nm

Side-mode suppression ratio

SMSR

30



dB

Average launch power, each lanea

AOPTX

-2.9


4.0

dBm

Outer Optical Modulation

Amplitude (OMAouter), each laneb

OMATX

-0.8



dBm

Launch power in OMAouter minus TDECQ, each lane


-2.2



dBm

Transmitter and dispersion eye closure

 for PAM4, each lane

TDECQ



3.4

dB

Average launch power of OFF transmitter, each lane

AOPOFF



-15

dBm

Extinction ratio, each lane

ER

3.5



dB

RIN21.4OMA




–136

dB/Hz

Optical return loss tolerance

RLTol



21.4

dB

Transmitter reflectancec

Reflectance_

Tx



-26

dB

Note:

a. Average launch power, each lane (min) is informative and not the principal indicator of signal strength. A transmitter with launch power below this value cannot be compliant; however, a value above this does not ensure compliance.

b. Even if the TDECQ < 1.4 dB, the OMAouter (min) must exceed these values.

c. Transmitter reflectance is defined looking into the transmitter.

3.2 Optical Receiver


Receiver optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Signaling rate, each lane

SR

53.125+/-100ppm

GBd

Modulation format


PAM4

-

Lane wavelengths

λ

1304.5

1311.0

1317.5

nm

Damage threshold, each lanea

DThd

5



dBm

Average receive power, each laneb

AOPRX

-5.9


4

dBm

Receiver reflectance

Reflectance_

Rx



-26

dB

Receiver sensitivity (OMAouter), each lanec

RxSens



-4.4

dBm

Stressed receiver sensitivity (OMAouter), each laned

SRS



-1.9

dBm

Conditions of stressed receiver sensitivity test:e

Stressed eye closure for PAM4 (SECQ), lane under test



3.4


dB

OMAouter of each aggressor lane



4.2


dBm

Rx LOS

LOS Assert

LOSA

-15


-7.9

dBm

LOS De-assert

LOSD



-7.4

dBm

LOS Hysteresis

LOSH

0.5


5

dB

Notes:

a. The receiver shall be able to tolerate, without damage, continuous exposure to an optical input signal having this average power level. The receiver does not have to operate correctly at this input power.

b. Average receive power, each lane (min) is informative and not the principal indicator of signal strength. A received power below this value cannot be compliant; however, a value above this does not ensure compliance.

c. Receiver sensitivity (OMAouter), each lane (max) is informative and is defined for a transmitter with SECQ of 0.9 dB.

d. Measured with conformance test signal at TP3 for the BER = 2.4E-4.

e. These test conditions are for measuring stressed receiver sensitivity. They are not characteristics of the receiver.


Digital Diagnostic Monitor Accuracy

The following characteristics are defined over recommended operating conditions.

Parameter

Accuracy

Unit

Internally Measured Transceiver Temperature

+/-3

Internally Measured Transceiver Supply Voltage

+/-3

%

Measured Tx Bias Current

+/-10

%

Measured Tx Output Power

+/-3

dB

Measured Rx Received Average Optical Power

+/-3

dB


Pin Assignment and Description

The OSFP module pinout and connector pin list are as follows:

800G OSFP DR8


Mechanical Dimensions

Package dimensions in mm are specified in OSFP MSA.

800G OSFP DR8

Package dimensions


Ordering Information

Part Number

Temperature

Range

Distance

Media Connector

Fiber Type

E/O

O/E

R12OSFP-800G-DR8

0 to 70℃

500m

Dual MPO-12

SMF

Siph PIC

Siph PD

R16OSFP-800G-DR8

0 to 70℃

500m

MPO-16

SMF

Siph PIC

Siph PD




想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
800G QSFP-DD 800G QSFP-DD SR8 850nm 100m MPO-16 APC
Features QSFP-DD Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface MPO-16 APC connector 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 QSFP-DD MSA Compliant Hot Pluggable QSFP-DD form factor Compliant to QSFP-DD-Hardware-Rev 6.3 MSA Compliant to CMIS 5.2 Support Protocol Compliant to IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃
工业级交换机 2光8电POE千兆工业级交换机 FW108GPS-2F
8*10/100/1000M自适应RJ45端口+2*千兆SFP端口(上行) FW108GPS-2F是一款工业全千兆管理型POE交换机,提供8个千兆POE端口,2个千兆光口,EMC工业4级的防护性能;波纹式高强度铝型材外壳、IP40等级、低功耗设计、抗震的导轨安装,-40℃-75℃的工作温度,可工作于恶劣环境。
100G QSFP28 ZR4 100Gb QSFP28 ZR4 80Km 1310nm LC Optical Transceiver
100G QSFP28 ZR4 optical transceiver module, support 100Gb/s and up to 80 km transmission on SM fiber, it works in high-speed IDC connection solutions, and so on. Features 4 lanes MUX/DEMUX design Support 100GBASE-ZR4 for line rate of 103.125Gbps and OTU4 for line rate of 111.81GbpsLANWDM EML laser and PIN receiver with SOA Aggregate bandwidth of >100Gbps Duplex LC connectors Compliant withIEEE 802.3-2012 Clause 88 standard IEEE 802.3bm CAUI-4 chip to module  electrical standard ITU-T G.959.1-2012-02 standard· Single +3.3V power supply operating Built-in digital diagnostic functions Temperature range 0°C to 70°C RoHS Compliant Part Support FEC(Forward Error Correction)
200G QSFP56 AOC cable 200G QSFP56 AOC Transceiverr
Features Up to 50Gbps data rate per channel by PAM4 modulation Support 200GAUI-4 electrical interface Integrated 850nm VCSEL array and PD array Single +3.3V power supply Case temperature range: 0 ~ +70℃ Hot-pluggable QSFP form factor RoHS complaint Applications Data centers and Cloud Networks Standards IEEE 802.3cd SFF 8679 CMIS4.0 or SFF8636
100G CFP Module 100G CFP2 ER4 Dual Rate 40km Module
Features Supports multi-rate (100GE and OTU4); from 103.1Gb/s to 111.8Gb/s aggregate; Lane bit rate 25.78 Gb/s 100GE, 27.95 Gb/s OTU4; Up to 40km transmission on SMF; LANWDM laser and PIN receiver with SOA; High speed I/O electrical interface (CAUI-4); MDIO interface with integrated Digital Diagnostic CFP2 MSA package with duplex LC connector; Single +3.3V power supply; Maximum power consumption 14W; Operating case temperature: 0 to +70 °C; Complies with IEEE802.3ba and ITU-T G.959.1; Complies with EU Directive 2015/863/EU;   Application 100GBASE-ER4;
网络分光器 16 OTAP 40G 多模 LC 网络分光器
产品特点 低插损,不影响数据流量包。 无需电源,无需IP地址,无需MAC地址,100%无源产品,性能安全可靠 安装和操作简单,非专业人士即可独立完成。 16个OTAP端口,支持8路40G主链路串接,数据流量复制;可替代8个交换机镜象端口。 成本低,集成度高
16路 双纤双向 C41-C56 DWDM 波分复用设备 (4联LC适配器) 16路 双纤双向 C41-C56 DWDM 波分复用设备 (4联LC适配器)
IL<3.5dB , 100GHZ DWDM MUX DEMUX Multiplexing of 16 Channels over a Dark Fiber Network Fully Compatible with All ITU-T 1G/10G/25G/40G/100G DWDM Optics Passive devices, No Power No Cooling Required Support Metro, Regional and Long Haul DWDM Networks
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系